When there's no water from your well, check three things in order: the well breaker (reset it once), the pressure gauge by the tank (zero means the pump isn't delivering), and the pressure switch (a clicking or chattering switch points to a control problem). If the pump hums or runs with no pressure, turn the breaker off to protect it and call.
Water Well Drilling Weatherford answers no-water calls around the clock across Parker County, and most of them start the same way: someone opens a tap and nothing comes out. Before you assume the well has run dry, work through these checks in order. They take about five minutes, and they tell us what to bring.
1. The well breaker
Find the breaker labeled well or pump in the main panel, or a separate disconnect near the well. If it has tripped, reset it once. If water comes back and the pump runs normally, you’re probably done, though a trip after a storm is worth mentioning when you call (see lightning damage to a well pump for what a surge can take out). If the breaker trips again immediately, leave it off. That usually means a short in the motor, wire or control box, and resetting it repeatedly can finish the job.
2. The pressure gauge
The gauge sits on the pipe near the pressure tank.
- Reads zero: the pump isn’t delivering water. The fault is the switch, the control box, the pump, or the water supply to the pump. Our guide on how to tell if a well pump is bad narrows it down.
- Reads normal (for example 40–60 psi) but no water in the house: the problem is between the tank and the taps, such as a closed valve, a clogged sediment filter or a frozen pipe.
- Keeps climbing past normal with the pump running: the switch isn’t turning the pump off. Turn off the breaker.
3. The pressure switch
The gray box on a short pipe by the tank is the pressure switch. Listen and look. A switch that clicks on and off rapidly points to a waterlogged tank or a clogged sensing port. A switch whose contacts are closed while the gauge stays at zero means power is going down the hole and the pump isn’t answering.
What the sounds tell you
Stand at the pressure tank with the breaker on and listen for a minute. This table is a field guide for narrowing the fault before you call; it is not a diagnosis.
| What you hear or see | Most likely area | What to do |
|---|---|---|
| Nothing at all, gauge at zero, breaker on | Pressure switch contacts, control box or capacitor, or the motor | Leave it; call. Pump-side parts usually sit above ground. |
| Pump hums or clicks but no water moves | Motor not starting, stuck pump, or a failed capacitor | Turn the breaker off to avoid burning the motor, then call. |
| Pump runs, gauge stays low or at zero | Split or disconnected pipe, worn pump, stuck check valve, or water level below the intake | Breaker off. Do not leave it running dry. |
| Switch chatters or clicks every few seconds | Waterlogged tank or clogged switch port | See signs of a bad pressure tank. |
| Gauge normal, no water at the taps | Closed valve, clogged filter or frozen line past the tank | Check the valve and filter, then the line. In a cold snap, see how to protect a well pump from freezing. |
Don’t rapid-cycle the breaker. Franklin Electric’s submersible motor manual notes that restarting a single-phase motor within about 5 seconds of power loss can trip its overload protector, and that the protector takes longer to reset than the starting switch. It also calls for a minimum one-minute run per start and limits the starts per day, because repeated starting heats the motor and wears the controls. One reset, then wait.
Check the tank’s air, too. Pentair’s ProSource Plus tank manual says that if the amount of water that comes out of the tank per cycle drops significantly, shut off power, drain the tank at a faucet, and check the air charge at the valve on top with a tire gauge. It should read 2 psi below the pump’s cut-in setting, so about 28 psi on a 30/50 switch. A tank at zero air pressure will make the pump short-cycle until it fails.
4. When to shut it off
Turn the breaker off and call if:
- the pump runs without building pressure (it may be running dry),
- the breaker trips as soon as it’s reset,
- you smell burning or see scorch marks at the switch or control box, or
- the yard is wet between the well and the house and the pump won’t stop (a broken line).
Submersible motors are cooled by the water flowing past them. Without it, they overheat fast. If your pump is an above-ground jet that has lost its prime, see how to prime a well pump before you call.
5. Could the well be dry?
It’s possible, especially in late summer on older, shallower wells, but it’s less common than a failed component. Signs include sputtering and air before the water stopped, and water that returns briefly after the well rests. We check by measuring the water level. The reading we compare it against is the well’s static level; see static water level in a well for what Parker County wells typically show. A well that was low from a hot, dry stretch can recover after it rests, but one that keeps dropping needs the pump lowered or a deeper well. See is my well going dry?.
What it usually turns out to be
Our well pump repair cost guide lists a pressure switch at $100 to $300 and a capacitor or relay at $150 to $400, none of which needs the pump pulled. A waterlogged tank is $800–$1,800 installed (see pressure tank replacement cost). A failed pump is $1,800–$4,500 at Parker County depths. Try the interactive well problem checker, or call. If it’s an emergency, see 24/7 emergency well pump repair.
Bottom line
Reset the breaker once, read the gauge, and listen at the switch. If the breaker trips again or the pump runs without building pressure, turn it off and call. Most no-water calls turn out to be a switch, a control box or a tank, not the well itself.