Size the pressure tank so the pump runs at least one minute per start. That takes about one gallon of drawdown per gpm for pumps up to ¾ hp and two for larger pumps. On a 30/50 switch, a 10 gpm pump needs a 32-gallon tank at ¾ hp or less and a 62-gallon tank above that (Amtrol sizing chart).
Water Well Drilling Weatherford sizes a pressure tank to the pump, not to the house’s square footage or to whatever tank was there before. What size pressure tank do I need? comes down to two numbers: your pump’s flow in gallons per minute and its horsepower. The charts below come from the motor and tank manufacturers.
Why does the pump need to run a full minute?
The pump motor needs at least one minute of run time per start to shed the heat of its starting current. Franklin Electric’s 2026 AIM manual for submersible motors sets that minimum and tells installers to pick the pump and tank size that keep starts per day as low as possible.
The same manual caps starts per 24 hours at 300 for single-phase motors up to ¾ hp and 100 for 1 to 5.5 hp motors. One hundred starts a day is one about every 14 minutes around the clock (our arithmetic). Franklin warns that excessive cycling shortens the life of pressure switches, relays and capacitors and can damage the motor’s spline and bearings. The pressure tank is what prevents that: it stores enough water for a full-minute run. A tank that is too small causes well pump short cycling.
How much water does each tank size deliver?
A pressure tank delivers roughly a quarter to a third of its nominal size between pump stops and starts. Amtrol’s Well-X-Trol specification sheet (form MC 7025, 2019) lists the drawdown for each tank at the three common switch settings:
| Tank volume | Drawdown at 30/50 | Drawdown at 40/60 | Drawdown at 50/70 |
|---|---|---|---|
| 20 gal | 6.2 gal | 5.4 gal | 4.7 gal |
| 32 gal | 9.9 gal | 8.6 gal | 7.6 gal |
| 44 gal | 13.6 gal | 11.8 gal | 10.4 gal |
| 62 gal | 19.2 gal | 16.6 gal | 14.6 gal |
| 86 gal | 26.6 gal | 23.0 gal | 20.3 gal |
| 119 gal | 36.8 gal | 31.9 gal | 28.1 gal |
That works out to about 31% of the tank at 30/50, 27% at 40/60 and 24% at 50/70 (our arithmetic from Amtrol’s figures). Other brands differ a little, so check the label on your tank. The higher the pressure setting, the less water each cycle delivers, which our 30/50 vs 40/60 pressure switch comparison explains.
To check any tank and setting yourself, the Water Systems Council’s tank sizing sheet gives the formula: acceptance factor = 1 − (pre-charge + 14.7) ÷ (cut-out + 14.7). With a 28 psi pre-charge on a 30/50 switch that is 0.34, and with 38 psi on 40/60 it is 0.29 (our arithmetic). Those are ceilings; published drawdowns run slightly lower.
What size pressure tank do I need for my pump?
Match the tank to the pump’s flow and horsepower. Amtrol’s chart sizes tanks for about one minute of run time on pumps up to ¾ hp and about two minutes on pumps over ¾ hp, so a larger pump needs roughly twice the tank at the same flow.
| Pump output | Up to ¾ hp, 30/50 | Up to ¾ hp, 40/60 | Over ¾ hp, 30/50 | Over ¾ hp, 40/60 |
|---|---|---|---|---|
| 5 gpm | 20 gal | 20 gal | 34 gal | 34 gal |
| 7 gpm | 26 gal | 26 gal | 44 gal | 62 gal |
| 10 gpm | 32 gal | 34 gal | 62 gal | 81 gal |
| 12 gpm | 44 gal | 44 gal | 81 gal | 81 gal |
| 15 gpm | 44 gal | 62 gal | 86 gal | 119 gal |
| 20 gpm | 62 gal | 81 gal | 119 gal | two 81-gal tanks |
Tank volumes are the Well-X-Trol models Amtrol selects for each case (form MC 7025, 2019). Two tanks piped together add up the same way as one large tank, and Amtrol’s own chart uses pairs for the largest pumps.
Pumps in Parker County are typically set near 200 ft (how deep are water wells in Parker County), so check the horsepower before you size from the left-hand columns.
What size tank does a three-bedroom house or a family of four need?
The tank is sized to the pump, and the pump is sized to the house. The Water Systems Council gives three ways to estimate household demand: count fixtures at 1 gpm each, count the fixtures in use at once at 3 gpm each, or count bathrooms at 4 gpm each. Use the largest result.
By the bathroom method, a home with 2½ baths counts as three (a half bath counts as one), so 3 × 4 = 12 gpm. A 12 gpm pump on a 30/50 switch then needs a 44-gallon tank at ¾ hp or less and an 81-gallon tank above that, from the chart above. The well also has to keep up with the pump; see what is a good gpm for a well for how well yield differs from pump output.
How do you find your pump’s flow and horsepower?
Check the pump’s model on your State Well Report or the service record; the horsepower is also printed on the control box of a three-wire pump. A tech can time how long the pump takes to raise the tank from cut-in to cut-out while no water is being used, which gives the delivered gallons per minute. Parker County wells vary. A shallow Peaster well and a deep Aledo well with the same horsepower pump can deliver very different flows.
How should the tank be set up?
- Pre-charge 2 psi below cut-in with the system drained: 28 psi on a 30/50 switch, 38 psi on 40/60 (Water Systems Council). Amtrol ships Well-X-Trol tanks at 38 psig, so a new tank going on a 30/50 switch has to be let down to 28. If you are raising the setting to get more pressure, our guide on how to increase well water pressure shows the full order of checks.
- Check the pre-charge yearly. Bladder tanks lose a little air over time.
- Keep the tank out of direct sun in an unvented well house. Heat shortens bladder life.
What are the common tank sizing mistakes?
- Replacing a failed tank with the same undersized tank.
- Sizing a 1 hp or larger pump from the one-minute columns.
- Raising the pressure switch setting without resetting the tank pre-charge (see how to adjust a well pressure switch for the right order).
- Adding irrigation to a system sized for a house.
See signs of a bad pressure tank, pressure tank replacement cost and well pressure tank replacement.
Bottom line
Find your pump's flow in gallons per minute and its horsepower, then read the chart: one minute of run time for pumps up to ¾ hp, two minutes above that. Set the pre-charge 2 psi below the cut-in pressure. When in doubt, go bigger: an oversized tank costs a little more, while an undersized one costs you a pump.
Questions about your own well? Call (817) 382-3840. A person answers 24/7.
Sources
- Franklin Electric, AIM Manual, 60 Hz Submersible Systems, 2026 edition (minimum one-minute run, maximum starts per 24 hours)
- Amtrol, Well-X-Trol specifications and sizing chart, form MC 7025 (04/19), retailer-hosted copy
- Water Systems Council, wellcare: Sizing a Pressure Tank (system demand methods, acceptance factor, pre-charge)